IEC60092 Offshore & Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Power Distribution Cables
600/1000V Single conductor Type P distribution cables
Construction
Conductor: Stranded copper conductor tin or alloy coated where necessary for the application , conductor per
ASTM or IEC 60228.
Separator tape: optional
Insulation: Cross-linked polyolefin(XLPO)according to IEEE 1580 2010 Type P,Type X, E, T, T/N, S, P, LSX and
LSE as option.
Shielding: optional
Jacket: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or
TPO jacket as option (optional for Type P with HD thicknesses).
Armor: optional and shall be nonmagnetic
Sheath: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P
or TPO sheath as option (optional except for tinned copper braid armoured cables).
Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO
jacket/sheath.
Table B.4—Typical dimensions and weights; single conductor 2000 V; Type P distribution cables
Conductor size in AWG or kcmil |
Unarmored | Armored | Armored and sheathed | |||
---|---|---|---|---|---|---|
Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | |
18 |
0.143 | 16 | 0.193 | 29 | 0.324 | 38 |
16 |
0.153 | 18 | 0.203 | 32 | 0.334 | 42 |
14 |
0.168 | 25 | 0.218 | 45 | 0.349 | 60 |
12 |
0.187 | 32 | 0.237 | 58 | 0.368 | 80 |
10 |
0.207 | 51 | 0.257 | 93 | 0.388 | 127 |
8 |
0.255 | 71 | 0.305 | 116 | 0.436 | 159 |
6 |
0.295 | 108 | 0.345 | 155 | 0.476 | 204 |
4 |
0.377 | 173 | 0.427 | 230 | 0.558 | 296 |
2 |
0.443 | 242 | 0.493 | 303 | 0.624 | 366 |
1 |
0.484 | 335 | 0.534 | 406 | 0.665 | 468 |
1/0 |
0.548 | 420 | 0.598 | 494 | 0.729 | 571 |
2/0 |
0.615 | 494 | 0.665 | 579 | 0.796 | 662 |
3/0 |
0.663 | 734 | 0.713 | 776 | 0.886 | 900 |
4/0 |
0.729 | 820 | 0.779 | 889 | 0.952 | 1036 |
262 kcmil |
0.888 | 945 | 0.938 | 1147 | 1.111 | 1295 |
313 kcmil |
0.954 | 1113 | 1.004 | 1332 | 1.177 | 1491 |
373 kcmil |
1.018 | 1419 | 1.068 | 1576 | 1.241 | 1741 |
444 kcmil |
1.094 | 1578 | 1.144 | 1816 | 1.317 | 1992 |
535 kcmil |
1.212 | 1976 | 1.262 | 2246 | 1.435 | 2425 |
646 kcmil |
1.3 | 2348 | 1.35 | 2559 | 1.523 | 2757 |
777 kcmil |
1.395 | 2795 | 1.445 | 3013 | 1.618 | 3205 |
1111kcmil |
1.652 | 3982 | 1.702 | 4129 | 1.938 | 4484 |
NOTE—These values are for reference purposes only and should not be construed as requirements.
Weights of armored constructions are based on bronze braid armor. It is recommended that the user/