IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Power Distribution Cables

600/1000V Single conductor Type P distribution cables

Construction

Conductor: Stranded copper conductor tin or alloy coated where necessary for the application , conductor per

ASTM or IEC 60228.

Separator tape: optional

Insulation: Cross-linked polyolefin(XLPO)according to IEEE 1580 2010 Type P,Type X, E, T, T/N, S, P, LSX and

LSE as option.

Shielding: optional

Jacket: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or

TPO jacket as option (optional for Type P with HD thicknesses).

Armor: optional and shall be nonmagnetic

Sheath: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P

or TPO sheath as option (optional except for tinned copper braid armoured cables).

Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO

jacket/sheath.

Table B.4—Typical dimensions and weights; single conductor 2000 V; Type P distribution cables


Conductor
size in
AWG or
kcmil
Unarmored Armored Armored and sheathed
Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft)

18

0.143 16 0.193 29 0.324 38

16

0.153 18 0.203 32 0.334 42

14

0.168 25 0.218 45 0.349 60

12

0.187 32 0.237 58 0.368 80

10

0.207 51 0.257 93 0.388 127

8

0.255 71 0.305 116 0.436 159

6

0.295 108 0.345 155 0.476 204

4

0.377 173 0.427 230 0.558 296

2

0.443 242 0.493 303 0.624 366

1

0.484 335 0.534 406 0.665 468

1/0

0.548 420 0.598 494 0.729 571

2/0

0.615 494 0.665 579 0.796 662

3/0

0.663 734 0.713 776 0.886 900

4/0

0.729 820 0.779 889 0.952 1036

262 kcmil

0.888 945 0.938 1147 1.111 1295

313 kcmil

0.954 1113 1.004 1332 1.177 1491

373 kcmil

1.018 1419 1.068 1576 1.241 1741

444 kcmil

1.094 1578 1.144 1816 1.317 1992

535 kcmil

1.212 1976 1.262 2246 1.435 2425

646 kcmil

1.3 2348 1.35 2559 1.523 2757

777 kcmil

1.395 2795 1.445 3013 1.618 3205

1111kcmil

1.652 3982 1.702 4129 1.938 4484

NOTE—These values are for reference purposes only and should not be construed as requirements.
Weights of armored constructions are based on bronze braid armor. It is recommended that the user/
specifier contact the manufacturer for manufacturer specific values.